Skip to main content
. 2018 Apr 7;18(4):1128. doi: 10.3390/s18041128

Table 5.

Fault diagnosis results for Dataset 3 for the proposed method and ALPIO when torque load = 2 hp.

Algorithms Proposed Method ALPIO
Crack Diameters (in) 0.007 0.014 0.021 0.007 0.014 0.021
Normal State 100% 100% 100% 85% 85% 85%
IR Faults 100% 100% 100% 73% 70% 75%
OR Fault 92% 85% 95% 75% 75% 75%
Ball Fault 93% 90% 90% 78% 81% 81%
Average 96.3% 93.8% 96.3% 77.8% 77.8% 79%