Table 1. EM data collection and refinement statistics of TRPC4DR.
Data collection | Data set 1 [Data set 2] |
---|---|
Microscope | Titan Krios (Cs corrected, XFEG) |
Voltage (kV) | 300 |
Camera | K2 summit (Gatan) |
Pixel size (Å) | 1.09 [1.09] |
Number of frames | 60 [40] |
Total electron dose (e-/Å2) | 69 [74] |
Number of particles | 132,622 |
Estimated defocus range | 0.844–2.931 |
Atomic model composition | |
Non-hydrogen atoms | 21,412 |
Protein atoms | 21,192 |
Ligand atoms | 236 |
Refinement (Phenix) | |
RMSD bond | 0.01 |
RMSD angle | 1.11 |
Model to map fit, CC mask | 0.80 |
Resolution (FSC@0.143, Å) | 3.6 |
Map sharpening B-factor (Å2) | −130.0 |
Validation | |
Clashscore | 3.53 |
Poor rotamers (%) | 0.17 |
Favoured rotamers (%) | 94.48 |
Ramachandran outliers (%) | 0.0 |
Ramachandran favoured (%) | 92.38 |
Molprobity score | 1.62 |
EMRinger score | 2.42 |