Skip to main content
. 2018 Mar 19;98(5):1374–1381. doi: 10.4269/ajtmh.17-0857

Table 1.

Clinical sensitivity, specificity, PPV, and NPV of LAMP, multiplex nPCR, RT-PCR, and RDT; and agreement (Cohen’s kappa) of these techniques vs. microscopy

Methods Positive Negative Sensitivity (%) (95% CI) Specificity (%) (95% CI) PPV (%) (95% CI) NPV (%) (95% CI) Cohen’s kappa (κ) of agreement
Microscopy
LAMP 100 85 98 100 0.909*
 Positive 145 3
 Negative 0 17
Multiplex nPCR 100 85 98 100 0.909*
 Positive 145 3
 Negative 0 17
RT-PCR 100 85 98 100 0.909*
 Positive 145 3
 Negative 0 17
RDT 96.6 85 98 77.4 0.752*
 Positive 140 3
 Negative 5 17

CI = confidence interval; LAMP = loop-mediated isothermal amplification; nPCR = nested PCR; NPV = negative predictive value; PCR = polymerase chain reaction; PPV = positive predictive value; RDT = rapid diagnostic test; RT-PCR = real-time PCR.

*

P value < 0.0001.