Skip to main content
. 2018 Feb 22;45(7):1091–1100. doi: 10.1007/s00259-018-3951-1

Table 2.

Diagnostic performance of expert visual analysis and automated analysis using standard software for the detection of coronary artery disease (n = 206)

Sensitivity Difference with expert Specificity Difference with expert Diagnostic accuracy Difference with expert
Expert 56.5 (45.8–66.8) 93.9 (87.8–97.5) 77.2 (70.8–82.7)
SSS NC 66.3 (55.7–75.8) P = 0.108 68.4 (59.1–76.8) P < 0.001* 67.5(60.6–73.8) P = 0.012*
SSS AC 67.0 (56.4–76.5) P = 0.064 71.9 (62.7–79.9) P < 0.001* 69.8 (63.0–76.0) P = 0.063
SDS NC 80.0 (70.3–87.7) P < 0.001* 50.0 (40.5–59.5) P < 0.001* 63.2 (56.2–69.9) P = 0.003*
SDS AC 86.5 (77.6–92.8) P < 0.001* 49.1 (39.6–58.7) P < 0.001* 65.5 (58.5–72.0) P = 0.023*
S-TPD NC 62.0 (51.2–71.9) P = 0.405 73.7 (64.6–81.5) P < 0.001* 68.4 (61.6–74.7) P = 0.020*
S-TPD AC 64.8 (54.1–74.6) P = 0.152 76.3 (67.4–83.8) P < 0.001* 71.2 (64.5–77.3) P = 0.134
I-TPD NC 65.6 (54.8–75.3) P = 0.108 69.9 (60.6–78.2) P < 0.001* 68.0 (61.1–74.3) P = 0.027*
I-TPD AC 65.9 (55.3–75.6) P = 0.108 65.8 (56.3–74.4) P < 0.001* 65.8 (58.9–72.3) P = 0.005*

Values are no. (95% confidence interval)

AC = attenuation correction; I-TPD = ischemic total perfusion deficit; NC = non-corrected; SDS = summed difference score; SSS = summed stress score; S-TPD = stress total perfusion deficit. *Indicating a significant difference with expert visual analysis (P < 0.05)