Table 2.
Summary of performed interventions and replaced aortic valve types in the surgery group. Baseline to follow-up MRI duration as well as surgery to follow-up MRI duration (in days) are provided for each subgroup.
AVR alone (n=5) | ARR-HA − (n=16) | ARR-HA + (n=12) | |
---|---|---|---|
Bioprosthesis | n=4 | n=12 | n=6 |
MRI f-u duration | 408 (334–594) days | 43 (27–102) days | 32 (20–40) days |
surgery to f-u MRI | 380 (321–559) days | 6 (5–18) days | 6 (5–17) days |
Mechanical valve | n=1 | n=0 | n=4 |
MRI f-u duration | 141 days | - | 56 (33–72) days |
surgery to f-u MRI | 92 days | - | 4 (3–5) days |
VS-ARR | n=4 | n=2 | |
MRI f-u duration | - | 33 (20–45) days | 191;1200 days |
surgery to f-u MRI | 4 (3–9) days | 6;3 days |
AVR: aortic valve replacement; ARR-HA−: aortic root replacement with no hemi-arch repair; ARR-HA+: aortic root replacement and hemi-arch repair; f-u: follow-up; VS-ARR: valve-sparing ARR