Skip to main content
. Author manuscript; available in PMC: 2018 May 18.
Published in final edited form as: J Neural Eng. 2018 Apr;15(2):026022. doi: 10.1088/1741-2552/aa9c8c

Table 1.

Experimental conditions used. The numbers in brackets indicate the number of trials for which each condition was presented. Conditions were applied simultaneously, for example real TMS, applied at 10% of detected ERD strength with feedback presented to the participant was used in 9 trials during the testing runs.

Trial type (trials) Delivery of TMS (trials) Feedback (trials)
Real TMS (90) 10% ERD (18) Yes (9)
No (9)
20% ERD (18) Yes (9)
No (9)
30% ERD (18) Yes (9)
No (9)
40% ERD (18) Yes (9)
No (9)
Fixed 33 ms after cue presentation (18) Yes (9)
No (9)
Sham TMS (90) 10% ERD (18) Yes (9)
No (9)
20% ERD (18) Yes (9)
No (9)
30% ERD (18) Yes (9)
No (9)
40% ERD (18) Yes (9)
No (9)
Fixed 33 ms after cue presentation (18) Yes (9)
No (9)
Rest (20) - -