Table 2.
Average Percent Errors of SIM and Scan Area Counts for Firefighter Samples
| Compound | Average Percent Error (%) | Standard Deviation | Number of Non-Detects (SIM Mode) | Number of Non-Detects (Scan Mode) |
|---|---|---|---|---|
| Benzene | 0.42 | 0.60 | 0 | 0 |
| Toluene | 3.24 | 4.88 | 0 | 0 |
| Ethylbenzene | 2.24 | 6.14 | 1 | 2 |
| m,p-Xylene | 3.74 | 11.80 | 1 | 2 |
| Styrene | 2.25 | 5.94 | 3 | 4 |
| o-Xylene | 2.27 | 6.28 | 1 | 1 |
| 4-Ethyltoluene | 24.14 | 24.27 | 15 | 19 |
| 1,3,5-Trimethylbenzene | 3.88 | 5.38 | 10 | 11 |
| Naphthalene | 6.50 | 13.10 | 4 | 3 |
| Acenaphthylene | 0.01 | 0.02 | 23 | 23 |
| Acenaphthene | 0.00 | - | 35 | 35 |
| Fluorene | 0.57 | 1.35 | 28 | 29 |
| Phenanthrene | 10.94 | 15.86 | 20 | 26 |
| Anthracene | 0.00 | - | 35 | 34 |
| Fluoranthene | 5.37 | 8.29 | 28 | 30 |
| Pyrene | 3.49 | 8.54 | 27 | 30 |