Table 2.
Characteristics of included hearing loss and tinnitus instruments.
Name of instrument | Number of questions | Number of levels | Number of domains | Instrument description |
---|---|---|---|---|
Hearing Measurement Scale (Einar-Jon et al., 2011; Einarsson et al., 2011) | 44 | 5 | 7 | Items rated always to never; questions weighted based upon importance; summary scores are HMS total, HMS disability, and HMS handicap |
Health Utilities Index (Barr et al., 2000; Fu et al., 2006; Kennedy et al., 2014) | 5 | 2 | 1 | Algorithm-converted responses to questions to attribute levels for HUI2 and HUI3 that were then used to generate single-attribute utility scores; no tinnitus domain |
Tinnitus Questionnaire for Auditory Brainstem Implant (Soussi & Otto, 1994) | 19 | Variable | 1 | Does not return an overall score |
Note. HMS = Hearing Measurement Scale; HUI = Health Utilities Index.