Table 3.

The Percent Difference in the Spherical S-Values Calculated with RAPID and the OLINDA/EXM Reference Values Inline graphic

  Percent difference between RAPID and OLINDA/EXM (%)
Sphere mass (g) 177Lu 131I 153Sm 90Y 111In 125I 18F 64Cu 89Zr 68Ga 124I 223Ra 211At 213Bi
1 0.2 0.1 −2.6 −7.2 6.3 2.0 −0.5 −1.2 3.4 −7.4 −8.8 6.0 3.4 3.0
10 −2.1 −0.6 −4.7 −4.8 4.0 −0.6 −1.8 −2.0 3.8 −5.6 −6.5 5.4 1.0 0.9
100 −1.1 −0.3 −4.0 −1.4 4.6 0.2 −0.2 −0.2 5.1 −2.5 −3.4 6.3 1.8 1.9
1000 −1.4 −0.5 −5.3 −1.0 1.4 1.1 −0.4 −0.2 3.6 −1.6 −2.3 6.4 1.8 2.1

A positive value indicates that the RAPID S-value was larger than the reference value.

OLINDA/EXM, Organ Level Internal Dose Assessment for EXponential Modeling; RAPID, Radiopharmaceutical Assessment Platform for Internal Dosimetry.