Table 3.
The Percent Difference in the Spherical S-Values Calculated with RAPID and the OLINDA/EXM Reference Values 
| Percent difference between RAPID and OLINDA/EXM (%) | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Sphere mass (g) | 177Lu | 131I | 153Sm | 90Y | 111In | 125I | 18F | 64Cu | 89Zr | 68Ga | 124I | 223Ra | 211At | 213Bi |
| 1 | 0.2 | 0.1 | −2.6 | −7.2 | 6.3 | 2.0 | −0.5 | −1.2 | 3.4 | −7.4 | −8.8 | 6.0 | 3.4 | 3.0 |
| 10 | −2.1 | −0.6 | −4.7 | −4.8 | 4.0 | −0.6 | −1.8 | −2.0 | 3.8 | −5.6 | −6.5 | 5.4 | 1.0 | 0.9 |
| 100 | −1.1 | −0.3 | −4.0 | −1.4 | 4.6 | 0.2 | −0.2 | −0.2 | 5.1 | −2.5 | −3.4 | 6.3 | 1.8 | 1.9 |
| 1000 | −1.4 | −0.5 | −5.3 | −1.0 | 1.4 | 1.1 | −0.4 | −0.2 | 3.6 | −1.6 | −2.3 | 6.4 | 1.8 | 2.1 |
A positive value indicates that the RAPID S-value was larger than the reference value.
OLINDA/EXM, Organ Level Internal Dose Assessment for EXponential Modeling; RAPID, Radiopharmaceutical Assessment Platform for Internal Dosimetry.