Skip to main content
. 2018 May 22;8:8018. doi: 10.1038/s41598-018-26333-4

Table 1.

Patients with positive results for JE MAC-ELISA or JEV RT-qPCR.

Patient number Age (yr) Sex JE MAC-ELISA (ISR)° JEV RT-qPCR (Ct value)
Admission Serum Convalescent Serum CSF Throat swab CSF Serum
NS2A NS3 NS2A NS3 NS2A NS3
1 19 M Pos (18.4) Pos (45.1) Pos (29.8) Neg Neg Neg Neg Neg Neg
2 50 M Pos (26.0) Pos (40.8) Pos (34.2) Neg Neg Neg Neg Neg Neg
3 33 M Pos (40.6) Neg (3.2) Pos (35.1) Neg Neg Neg Neg
4 7 M Pos (17.7) Pos (44.4) Neg Neg Neg Neg
5 16 M Pos (7.9) Pos (18.0) Pos (21.6) Pos (32) Pos (37) Neg Neg
6 13 M Pos (11.3) Pos (27.9) Pos (60.3) Neg Neg Neg Neg
7 14 M Pos (21.7) Pos (38.2) Neg Neg Neg Neg Neg Neg
8 3 F Pos (13.6) Pos (33.9) Neg Neg Neg Neg
9 3 M Pos (18.0) Pos (41.8) Neg Neg Neg
10 13 M Pos (22.3) Pos (42.8) Pos (36) Neg Neg
11 23 M Pos (6.3) Neg (4.8) Pos (6.4) Neg Neg

M: male, F: female. CSF: cerebrospinal fluid. °Anti-JEV IgM detection using JE Detect™ IgM Antibody Capture ELISA Kit (InBios, Washington, USA). Positive (Pos) = Anti-JEV IgM positive, negative (Neg) = Anti-JEV IgM negative or equivocal, with ISR (Immune status Ratio) cut-offs calculated according to the manufacturer’s instructions. RT-qPCR negative (Neg) = no amplification curve or curve with a Cq > 40. RT-qPCR positive (Pos) = amplification curve with Cq < 40. “−“ = no sample available for testing due to small sample volume collected and/or the use in its entirety for previous assays.