Skip to main content
. 2018 May 18;10(2):157–166. doi: 10.4055/cios.2018.10.2.157

Table 4. Clinical Results at Last Follow-up between the Fixed-Loop Group and the Adjustable-Loop Group.

Variable Fixed-loop group (n = 22) Adjustable-loop group (n = 17) p-value
IKDC subjective score 79.43 ± 12.0 78.6 ± 17.7 0.931
Tegner-Lysholm score 82.3 ± 13.3 85.7 ± 17.3 0.624
IKDC objective score 0.973
 A 14 (63.6) 11 (64.7)
 B 7 (31.8) 5 (29.4)
 C 1 (4.6) 1 (5.9)
 D 0 0
Lachman test 0.240
 Negative 16 (72.7) 15 (88.2)
 1+ 6 (27.3) 2 (11.8)
 2+ 0 0
 3+ 0 0
Pivot shift test 0.587
 Negative 18 (81.8) 15 (88.2)
 1+ 4 (18.2) 2 (11.8)
 2+ 0 0
 3+ 0 0

Values are presented as mean ± standard deviation or number (%).

IKDC: International Knee Documentation Committee.