Table 4. Clinical Results at Last Follow-up between the Fixed-Loop Group and the Adjustable-Loop Group.
Variable | Fixed-loop group (n = 22) | Adjustable-loop group (n = 17) | p-value |
---|---|---|---|
IKDC subjective score | 79.43 ± 12.0 | 78.6 ± 17.7 | 0.931 |
Tegner-Lysholm score | 82.3 ± 13.3 | 85.7 ± 17.3 | 0.624 |
IKDC objective score | 0.973 | ||
A | 14 (63.6) | 11 (64.7) | |
B | 7 (31.8) | 5 (29.4) | |
C | 1 (4.6) | 1 (5.9) | |
D | 0 | 0 | |
Lachman test | 0.240 | ||
Negative | 16 (72.7) | 15 (88.2) | |
1+ | 6 (27.3) | 2 (11.8) | |
2+ | 0 | 0 | |
3+ | 0 | 0 | |
Pivot shift test | 0.587 | ||
Negative | 18 (81.8) | 15 (88.2) | |
1+ | 4 (18.2) | 2 (11.8) | |
2+ | 0 | 0 | |
3+ | 0 | 0 |
Values are presented as mean ± standard deviation or number (%).
IKDC: International Knee Documentation Committee.