Table 2.
Summary of findings obtained for the spatial accuracy and contact durations (CD in ms) in the patient and in the control groups as a function of the different rhythmic complexity conditions.
| Spatial accuracy | HC | SZ | Fisher’s F | p | |
|---|---|---|---|---|---|
| Contact duration (ms) | |||||
| Isochronous sequences (500 ms) | 152 ± 47 | 199 ± 51 | |||
| 12.961 | 0.001 | 0.117 | |||
| Non-isochronous sequences (300/600 ms) | 129 ± 41 | 146 ± 42 | |||
| Area of ellipses (mm2) | |||||
| Isochronous sequences (500 ms) | 62 ± 19 | 97 ± 49 | |||
| 21.595 | <0.001 | 0.181 | |||
| Non-isochronous sequences (300/600 ms) | 81 ± 21 | 142 ± 90 | |||
SZ, patients with schizophrenia; HC, healthy controls. Analyses of variance were conducted on both contact duration and area of ellipses to reveal main effects of pathology.