Skip to main content
. 2018 May 23;143(5):3068–3078. doi: 10.1121/1.5038278

TABLE II.

Broadband reverberation times (T60) and clarity indices (C50), speech transmission indices (STI), and broadband interaural cross-correlation (IACC) for each room and configuration.

Room R2 R3 R4
Conf. A B C A B C A B C
T60 (s) 0.49 0.47 0.47 1.22 1.15 1.15 2.38 2.27 2.27
C50 (dB) 13.86 14.67 14.23 3.95 4.77 4.27 −0.79 0.37 −0.09
IACC 0.906 0.909 0.908 0.536 0.609 0.585 0.330 0.400 0.384
STI 0.929 0.924 0.926 0.723 0.738 0.709 0.596 0.604 0.566