Skip to main content
. 2018 May 17;12:317. doi: 10.3389/fnins.2018.00317

Figure 5.

Figure 5

ROC curve of the dominant frequency as a performance measure to differentiate Parkinson's disease tremor and essential tremor, assuming targeting a diagnosis of essential tremor over Parkinson's disease. (A) Under the PSD estimate with Posture 1 (P1). AUC is 0.657 (95%CI 0.606–0.704) with a standard error of 0.025. (B) Under the bispectrum estimate with Posture 1 (P1). AUC is 0.671 (95%CI 0.621–0.716) with a standard error of 0.024. (C) Under the PSD estimate with Posture 2 (P2). AUC is 0.892 (95%CI 0.862–0.921) with a standard error of 0.015. (D) Under the bispectrum estimate with Posture 2 (P2). AUC is 0.870 (95%CI 0.835–0.902) with a standard error of 0.017.