Skip to main content
. 2018 May 25;9(5):154. doi: 10.1038/s41424-018-0021-8

Table 2.

Measurement data in the portal vein and the left gastric vein

Flow direction (Forward/bidirectional/reverse) Diameter (mm) Velocity (cm/s) Flow volume (mL/min)
Portal vein (n = 229) 209 (91.3%)/15 (6.5%)/5 (2.2%) 10.9 ± 2.0 (2.7–16.3) 12.4 ± 2.9b (6.3–22.5) 741.5 ± 277.8b (255–1970)
Left gastric vein (n = 164)a 12 (7.3%)/15 (9.1%)/137 (83.6%) 5.4 ± 1.7 (0.9–11.6) 12.4 ± 3.5c (5.2–25.8) 220.8 ± 174.5c35–1124

Data are expressed as number or mean ± SD (percentage or range).

a Left gastric vein was not detected in 65 patients

b Velocity and flow volume in the portal vein showing forward flow direction

c Velocity and flow volume in the left gastric vein showing reverse flow direction