Skip to main content
. 2018 Mar 12;25(15):14595–14605. doi: 10.1007/s11356-018-1614-1

Table 2.

Percentage of boats with mean and median values (6–8 measurements) of copper on plastic boat hulls

Country and no. of sites Mean values of copper
% boats in different ranges
Median values of copper
% boats in different ranges
< 100 μg Cu/cm2
St dev in brackets
> 4000 μg Cu/cm2
St dev in brackets
> 8000 μg Cu/cm2
St dev in brackets
< 100 μg Cu/cm2
St dev in brackets
> 4000 μg Cu/cm2
St dev in brackets
> 8000 μg Cu/cm2
St dev in brackets
Denmark 1 (n = 25) 0 88 56 0 92 56
Denmark 2 (n = 28) 0 75 39 0 79 39
Denmark 3 (n = 28) 0 61 57 4 64 54
Mean DK (n = 3) 0 75 (14) 51 (10) 1.3 (2.3) 78 (14) 50 (9.3)
Finland 1 (n = 52) 8 73 48 10 69 48
Finland 2 (n = 53) 0 79 66 0 79 62
Finland 3 (n = 51) 0 75 53 2 71 51
Mean FI (n = 3) 3 (4.6) 76 (3.2) 56 (9.3) 4 (5.3) 73 (5.4) 54 (7.5)
Germany 1 (n = 50) 0 88 68 0 88 66
Germany 2 (n = 90) 0 89 54 0 89 56
Mean DE (n = 2) 0 88 (0.6) 61 (9.6) 0 88 (0.6) 61 (7.4)
SE, freshwater (n = 202) 29 18 6 29 18 6
SE, brackish water (n = 268) 11 37 17 11 37 17
SE, marine water (n = 202) 1 72 55 1 72 55
Mean Sweden (n = 3) 14 (14) 42 (27) 26 (26) 14 (14) 42 (27) 26 (26)

Data for Sweden are from Ytreberg et al. 2016 and based on a single measurement per boat

LOQ = 100 μg Cu/cm2

The mean values are presented in italic with the standard deviation in brackets