Skip to main content
. 2018 May 29;8:8297. doi: 10.1038/s41598-018-26627-7

Table 2.

Informative patterns of Joi-GAM-Class and corresponding selected regions.

Regions Measurement Type Patterns Frequency (%) Normalized-Accuracy Matched-Accuracy
1 2 3 4
Lateral ventricle Volume X X X X 99.0 60.1 66.2
Mid posterior corpus callosum Volume X X X X 97.9 63.0 63.2
Centrum semiovale Volume X X X 99.2 61.1 55.9
Central corpus callosum Volume X X X 79.3 64.0 64.7
Anterior corona radiata Fractional anisotropy X X 96.3 80.0 67.6
Posterior thalamic radiation Fractional anisotropy X X 58.0 75.4 66.2
Fornix Axial diffusivity X 90.0 67.1 66.2
Cingulate gyrus Volume X 61.4 53.0 51.5
Frequency (%) 97.8 80.4 54.7 52.9
Normalized-Accuracy 65.0 64.8 74.6 79.4
Matched-Accuracy 69.1 66.2 70.6 79.4

Accuracy scores in bold were significantly different from chance (p ≤ 0.002).