Skip to main content
. 2018 Apr 29;11(5):702. doi: 10.3390/ma11050702

Table 2.

Performance of the 10 wt % poly(BPE)/g-C3N4 composite-modified GCE for individual and simultaneous determination of Cd2+ and Pb2+.

Types Analytes Linear Range (μM) Linear Regression Equation R2 Detection Limit (μM)
Individual determination Cd2+ 0.1–6.8 I (μA) = 1.08782 + 7.63612c (μM) 0.99707 0.00970
Pb2+ 0.1–6.4 I (μA) = 0.37986 + 11.1397c (μM) 0.99661 0.00327
Simultaneous determination Cd2+ 0.12–7.2 I (μA) = 0.26776 + 4.11513c (μM) 0.99740 0.0180
Pb2+ 0.08–7.2 I (μA) = 0.73646 + 11.28023c (μM) 0.99599 0.00324