Skip to main content
. 2018 May 16;11(5):815. doi: 10.3390/ma11050815

Table 2.

The fitted parameters of the equivalent circuit model by the Nyquist plots.

Parameters As-Cast Pre-Extrusion
Heat Treated
As-Extruded Post-Extrusion
Heat Treated
Rs (Ω·cm2) 8.68 16.52 8.857 13.36
Rc (Ω·cm2) 4.74 4.27 5.50 0.098
Cc (F·cm2) 3.38 × 10−7 2.32 × 10−7 2.90 × 10−7 1.85 × 10−13
CPE-T (μΩ−1·cm−2·s−1) 2.55 × 10−5 2.32 × 10−5 3.00 × 10−5 2.18 × 10−5
CPE-P 0.91279 0.90695 0.91894 0.91298
Rct (Ω·cm2) 339.8 350.8 343 548.2
RL (Ω·cm2) 1110 640.6 - 1716
L (H·cm2) 9989 9261 - 22,845
Rf (Ω·cm2) 63.3 153.2 50.3 133.7
Cf (F·cm2) 0.0074 0.0038 0.0073 0.0034
chisq 0.0020 0.0014 0.0033 0.0011