Table 7. Clinical data of XLRS patients showing non-secreted RS1 profile.
FAMILY/ PATIENT | EYE | VISUAL ACUITY | REFRACTIVE ERROR | FUNDUS FINDINGS | b/a RATIO—ERG |
---|---|---|---|---|---|
F1/P1 | OD | 6/38 | 5.5 | FS+PS | 0.82* |
OS | CF at 1 meter | 7.5 | FS+PS (RD) | 0.99 | |
F2/P2 | OD | 6/24 | 2.5 | FS | 1.23 |
OS | 6/24 | 1.25 | FS | 1.28 | |
F3/P3 | OD | 6/12 | 2 | FS | 1.14 |
OS | 6/12 | 0.75 | FS | 1.11 | |
F3/P4 | OD | 6/18 | 2.75 | FS | 0.96 |
OS | 6/18 | 2.75 | FS | 1.09 | |
F4/P5 | OD | CF at 3 meters | 11.5 | FS+PS | Not tested |
OS | Perception of Light | FS+PS (RD) | Not tested | ||
F5/P6 | OD | 6/18 | 0.75 | FS | 1.21 |
OS | 6/18 | 0.75 | FS | 1.3 | |
F6/P7 | OD | 6/60 | 8 | FS+PS | 0.94* |
OS | 6/18 | 8 | FS+PS (RD) | 0.97* | |
F7/P8 | OD | 6/18 | 5.5 | FS+PS | 0.75* |
OS | No Perception of light | not measurable | FS+PS (RD) | Non recordable | |
F8/P9 | OD | 3/60 | -14 | FS+PS | 1.6 |
OS | 6/24 | -0.75 | FS+PS | 1.34 | |
F8/P10 | OD | 6/45 | -6 | FS+PS | Not tested |
OS | 6/18 | -1 | FS+PS | Not tested |
OD, right eye; OS, left eye; CF, counting fingers; Refractive error in diopters, FS, foveal schisis; PS, peripheral schisis; RD, retinal detachment;
*Electronegative wave form.