Skip to main content
. 2018 May 8;18(5):1460. doi: 10.3390/s18051460

Table 3.

The standard deviation values (σ) of different SRs and CRs in time domain (√ means the situation fits with 3σ criterion, X means not).

CR (%) 20 30 40 50 60 70 80
20 MHz SR σ 0.4322 0.3878 0.4217 0.3930 0.4593 6.4072 9.3127
Fit 3σ criterion X X
25 MHz SR σ 0.3677 0.4539 0.3876 0.4211 0.4125 4.5018 5.3882
Fit 3σ criterion X X
33 MHz SR σ 0.4482 0.3975 0.4421 0.3903 0.3759 0.5225 3.5697
Fit 3σ criterion X
50 MHz SR σ 0.3855 0.4203 0.3547 0.3971 0.3632 0.4125 3.4338
Fit 3σ criterion X