Skip to main content
. 2018 May 5;18(5):1437. doi: 10.3390/s18051437

Table 2.

Correct rate for gauging the damage level of each story. (The observed maximum damage level and the identified fundamental natural frequency are also listed.).

Case Input (gal) Setra
(Correct Stories/Total Stories)
P-Alert
(Correct Stories/Total Stories)
Pseudo-Synchronized P-Alert
(Correct Stories/Total Stories)
Observed Maximum Damage Level Identified Fundamental Natural Frequency
Case 1 EL50 6/6 6/6 6/6 None 3.77
Case 1 EL100 6/6 5/6 6/6 Slight 3.62
Case 1 EL150 4/6 3/6 3/6 Moderate 2.88
Case 1 EL200 5/6 3/6 5/6 Moderate 2.78
Case 1 EL250 3/6 0/6 2/6 Moderate 1.82
Case 1 EL300 4/6 2/6 4/6 Extensive 1.11
Case 1 EL350 2/6 4/6 4/6 Extensive 0.75
Case 2 EL50 6/6 6/6 6/6 None 3.42
Case 2 EL100 6/6 6/6 6/6 None 3.41
Case 2 EL150 5/6 5/6 6/6 Moderate 3.21
Case 2 EL200 6/6 1/6 2/6 Moderate 2.73
Case 2 EL250 6/6 1/6 2/6 Moderate 2.05
Case 2 EL300 5/6 3/6 5/6 Extensive 1.15
Case 2 EL350 5/6 3/6 5/6 Extensive 0.81
Case 3 EL200 6/6 1/6 3/6 Moderate 2.45
Case 3 EL350 5/6 1/6 4/6 Extensive 1.16
Case 3 EL400 5/6 2/6 5/6 Extensive 0.82
Case 4 EL250 5/6 2/6 3/6 Moderate 1.95
Case 4 EL400 6/6 2/6 2/6 Extensive 0.85
Case 4 EL450 6/6 3/6 6/6 Extensive 0.76
Total 102/120 59/120 85/120 - -
Correct rate (%) 85.0 49.2 70.8 - -