Table 3.
Case No. | Input (gal) | Setra (Estimated/Reference Damage Level) |
Correct (Y/N) | P-Alert (Estimated/Reference Damage Level) |
Correct (Y/N) |
---|---|---|---|---|---|
Case 1 | EL50 | Safe/Safe | Y | Safe/Safe | Y |
Case 1 | EL100 | Safe/Safe | Y | Safe/Safe | Y |
Case 1 | EL150 | Safe/Non-safe | N | Non-safe/Non-safe | Y |
Case 1 | EL200 | Non-safe/Non-safe | Y | Non-safe/Non-safe | Y |
Case 1 | EL250 | Non-safe/Non-safe | Y | Non-safe/Non-safe | Y |
Case 1 | EL300 | Non-safe/Non-safe | Y | Non-safe/Non-safe | Y |
Case 1 | EL350 | Non-safe/Non-safe | Y | Non-safe/Non-safe | Y |
Case 2 | EL50 | Safe/Safe | Y | Safe/Safe | Y |
Case 2 | EL100 | Safe/Safe | Y | Safe/Safe | Y |
Case 2 | EL150 | Safe/Safe | Y | Safe/Safe | Y |
Case 2 | EL200 | Non-safe/Non-safe | Y | Non-safe/Non-safe | Y |
Case 2 | EL250 | Non-safe/Non-safe | Y | Non-safe/Non-safe | Y |
Case 2 | EL300 | Non-safe/Non-safe | Y | Non-safe/Non-safe | Y |
Case 2 | EL350 | Non-safe/Non-safe | Y | Non-safe/Non-safe | Y |
Case 3 | EL200 | Safe/Safe | Y | Safe/Safe | Y |
Case 3 | EL350 | Non-safe/Non-safe | Y | Non-safe/Non-safe | Y |
Case 3 | EL400 | Non-safe/Non-safe | Y | Non-safe/Non-safe | Y |
Case 4 | EL250 | Non-safe/Non-safe | Y | Non-safe/Non-safe | Y |
Case 4 | EL400 | Non-safe/Non-safe | Y | Non-safe/Non-safe | Y |
Case 4 | EL450 | Non-safe/Non-safe | Y | Non-safe/Non-safe | Y |
Correct rate (%) | - | 95.0 | - | 100.0 |