Skip to main content
. Author manuscript; available in PMC: 2019 Apr 1.
Published in final edited form as: Control Eng Pract. 2018 Mar 14;73(April 2018):149–160. doi: 10.1016/j.conengprac.2018.01.008

Table 2.

Model parameter values associated with the individualized models (mean (SD)). Full: fully individualized model. Partial: partially individualized model.

Model αua
[·]
αυ
[·]
Kp
[min−1]
Ki
[min−2]
θ1
[ml]
θ2
[min/ml]
θ3
[ml−1]
θ4
[·]
T P R0
[mmHg·min/l]
B P0
[mmHg]
Crystalloid Full 2.3 (2.0) 1.1 (0.9) 0.1 (0.1) 17e-4 (1e-3) 12.2 (5.4) −0.048 (0.046) 0.28 (0.12) −422 (231) 16.5 (6.12) 82.9 (7.14)
Partial 1.56 (0.67) 1.09 (0.83) 0.13 (0.10) 31e-4 (0) 13.0 (0) −0.045 (0.044) 0.27 (0.13) −421 (246) 17.4 (6.66) 82.2 (7.59)

Colloid Full −0.20 (0.26) 0.93 (0.52) 0.15 (0.13) 63e-4 (41e-4) 14.7 (5.46) −0.063 (0.041) 0.31 (0.12) −410 (165) 14.7 (3.88) 91.1 (22.4)
Partial −0.20 (0.23) 0.90 (0.37) 0.20 (0.11) 31e-4 (0) 13.0 (0) −0.072 (0.043) 0.32 (0.13) −442 (228) 17.0 (7.56) 94.5 (31.2)
a

Significantly different between crystalloid and colloid. (p < 0.05).