Skip to main content
. 2018 Jun 5;8:9. doi: 10.1186/s40945-018-0048-x

Table 5.

Intra-rater reliability of the ultrasound measurements (direct method) in the feasibility study for the TD group (n = 15). Data were expressed as typical error and intra-class coefficients (ICC) with their 95% confidence intervals (CI) and mean differences ± standard deviation (SD)

Muscle & Stage Typical Error 95% CI ICC 95% CI Mean diff ± SD
EO R 0.62 (0.06–0.22) 0.80 (0.66–0.96) −0.13 ± 0.08
EO Ac 0.60 (0.08–0.20) 0.82 (0.76–0.97) −0.02 ± 0.09
IO R 0.64 (0.05–0.22) 0.81 (0.86–0.98 −0.16 ± 0.06
IO Ac 0.62 (0.06–0.21) 0.79 (0.65–0.95) −0.09 ± 0.08
TrA R 0.64 (0.04–0.20) 0.84 (0.68–0.98) 0.09 ± 0.09
TrA Ac 0.64 (0.06–0.22) 0.85 (0.72–0.94) 0.09 ± 0.09
RA R 0.66 (0.08–0.24) 0.85 (0.75–0.98) −0.10 ± 0.09
RA Ac 0.63 (0.06–0.20) 0.86 (0.76–0.96) −0.01 ± 0.03

Key: EO R external oblique resting stage, EO Ac external oblique active stage, IO R internal oblique resting stage, IO Ac internal oblique active stage, TrA R transverse abdominis resting. TrA Ac transverse abdominis active stage, RA R rectus abdominis resting stage, RA Ac rectus abdominis active stage