AUC and OR for Bronchiectasisa

QCT Measurement AUC 95% CI OR 95% CI P
BA ratio
 Whole-lung 0.90 0.81-0.99 1.11 1.05-1.18 .0002
 Generation
 4 0.83 0.72-0.94 1.06 1.03-1.10 .0002
 5 0.79 0.65-0.93 1.06 1.06-1.10 .0004
 6 0.89 0.80-0.98 1.08 1.04-1.13 .0005
WT
 Whole lung 0.74 0.61-0.87 1.14 1.05-1.24 .002
 Generation
 4 0.75 0.62-0.88 1.12 1.04-1.20 .003
 5 0.72 0.58-0.86 1.10 1.03-1.17 .006
 6 0.68 0.52-0.84 1.10 1.02-1.18 .01
WA%
 Whole lung 0.73 0.58-0.87 1.12 1.02-1.23 .02
 Generation
 4 0.75 0.63-0.88 1.11 1.02-1.20 .01
 5 0.71 0.57-0.85 1.10 1.02-1.19 .02
 6 0.55 0.39-0.71 1.02 0.95-1.08 .63

AUC = area under the receiver operating characteristic curve. See Table 2 legend for expansion of other abbreviations.

a

Models included cases, control patients, and all airway types.