Table 1.

Sensitivity, response time and recovery time of the sensor measured at different reverse bias voltages of −2, −4 and −6 V for different H2 concentrations.

–2 V
–4 V
–6 V
H2 (ppm) ΔR/Ro (%) response time (s) recovery time (s) ΔR/Ro (%) response time (s) recovery time (s) ΔR/Ro (%) response time (s) recovery time (s)
2000 11.91 >300 >300 17.83 98 96 32.94 60 49
1800 7.39 >300 >300 9.05 100 100 19.44 59 49
1600 6.47 >300 >300 8.23 98 99 18.13 57 54
1400 4.09 >300 >300 5.00 99 98 10.82 60 65
1200 3.35 >300 >300 3.85 100 92 8.85 50 63
1000 2.30 >300 >300 3.03 92 100 5.25 47 53
800 2.03 >300 >300 1.99 93 100 4.32 53 65
600 2.11 >300 >300 1.32 >300 >300 2.78 50 50
400 1.38 >300 >300 1.24 >300 >300 1.93 54 62
200 1.50 >300 >300 1.02 >300 >300 2.37 50 65