Subject area |
Water quality |
More specific subject area |
Water fluoride |
Type of data |
Tables, Figures |
How data was acquired |
Analysis of all water samples were done according to the Standard Methods for Examination of Water and Wastewater. Anions and cations including magnesium, calcium, and chloride as well as temporary and permanent hardness were measured using titration method. Turbidity meter (model Hach 50161/co 150 model P2100Hach, USA) was used to analysis of electrical conductivity. Also, determining of fluoride, nitrate, and sulfate concentration in comparison with internal standards were done using Hach DR5000 spectrophotometer. |
Data format |
Raw, Analyzed |
Experimental factors |
All water samples were stored in polyethylene bottles in a dark place at room temperature until analysis. |
Experimental features |
Determine the concentration levels of fluoride |
Data source location |
Ardakan region, Yazd province. Iran |
Data accessibility |
Data are included in this article |