Skip to main content
. Author manuscript; available in PMC: 2019 Jun 12.
Published in final edited form as: Lab Chip. 2018 Jun 12;18(12):1671–1689. doi: 10.1039/c7lc01248a

Table 5.

Estimated permeability of different membranes used in tissue barrier and co-culture models, calculated based on pore size, porosity, and membrane thickness. IP-DiLL(IP-dipin Laser Lithography photoresist), PC (Polycarbonate), Pnc-Si (Porous nanocrystalline Silicon), PDMS (Polydimethylsiloxane), SiN (Silicon nitride)

Material Commercially available? Permeability or Conductance Diffusive/Hydraulic/Electric Tissue type Goal of the study
IP-DiLL photoresist No –two photon lithography 1.1 · 10−5 s/m3
4.5 · 10−6 pas · s/m3
2.2 · 105 S−1
bEnd.3 and U87 glioblastoma On chip BBB127
PC Yes – Track etched – AR- Brown 3.5 · 10−8 s/m3
3.2 · 10−9 pas · s/m3
270 S−1
CHO cells Rapid shear-free delivery of soluble factors over large culture area20
PDMS No – Custom casting 5.7 · 10−7 s/m3 pas
2.3 · 10−5 · s/m3
1.1 · 104 S−1
Caco-2 BEE On chip TEER measurement correction104
pnc-Si and SiN No – rapid phase transition and lithography 8.6 · 10−4 s/m3
8.6 · 10−8 pas · s/m3
1.0 · 107 S−1
neutrophils Shear-free chemotaxis and cell labeling21