Skip to main content
. 2018 May 4;19:398–408. doi: 10.1016/j.dib.2018.04.103

Table 2.

Datasets of ground vibration measurements and design parameters for blasting at Offa Quarry.

Data monitoring points Shot to monitored distance (D) [metre] Charge weight (in 50 holes) (W) [kg] Peak Particle velocity (mm/s)
Scaled distance D/W12
Vertical [mm/s] Longitudinal [mm/s] Transversal [mm/s] Vectoral Sum [mm/s]
1 300 1450 90.85 90.75 90.25 156.95 7.88
2 350 1450 71.05 71.30 70.95 100.94 9.19
3 400 1400 55.75 55.75 55.08 96.18 10.69
4 450 1450 47.50 47.40 47.35 82.13 11.82
5 500 1400 39.05 39.15 38.95 67.64 13.36
6 550 1500 35.45 35.55 35.75 60.63 14.20
7 600 1200 25.70 25.85 27.45 45.63 17.32
8 650 1850 32.05 32.00 32.05 55.48 15.11
9 700 1850 28.40 28.45 28.35 49.19 16.27
10 750 950 14.95 14.90 14.85 25.81 24.33
11 800 1350 17.80 17.70 17.85 30.80 21.77
12 850 1250 15.25 15.20 15.15 26.33 24.04
13 900 1250 13.95 13.80 12.95 23.51 25.46
14 950 1500 14.75 14.85 14.25 25.32 24.53
15 1000 1500 13.50 13.25 13.35 23.30 25.82
16 1050 1750 14.25 13.95 14.05 24.39 25.10
17 1100 2350 16.75 16.05 16.25 28.32 22.69
18 1150 1350 10.00 9.85 10.05 17.26 31.30
19 1200 1450 9.90 9.85 9.25 16.75 31.51
20 1250 2755 15.50 15.20 14.95 26.36 23.81