Skip to main content
. 2018 Jun 13;8:9046. doi: 10.1038/s41598-018-27418-w

Table 2.

Diffusion times (tD), derived diffusion coefficients (Dc), hydrodynamic diameters (dH) and relative cross-correlation FCCS/ACF_G. The diffusion times refer to the curves in Fig. 3. NPs were labeled with ATTO633. Measurements were performed with NPs with PC after the excess of BSA was removed from the dispersion by centrifugation. ConA was added to the PC and measurements were performed in situ.

tD [µs]a Dc [µm2/s]b dHc [nm] FCCR/ACF_G tD [µs]a Dc [µm2/s]b dHc [nm] FCCR/ACF_G
PC BSA 1870 ± 80 5.2 ± 0.2 65.6 ± 2.5 PC BSAd 1163 ± 230 8.4 ± 1.5 40.6 ± 7.5 0.17
+ConAd 5 min 1242 ± 56 7.9 ± 0.3 43.2 ± 1.6 0.73 +ConA 5 min 2936 ± 180 3.3 ± 0.1 103.4 ± 3.1 0.12
+ConAd 90 min 762 ± 67 12.9 ± 1.0 26.4 ± 2.1 0.63 +ConA 90 min 1162 ± 47 8.4 ± 0.2 40.6 ± 1.0 0.03
+ConAd 120 min 1186 ± 42 8.2 ± 0.4 41.6 ± 2.1 0.53 +ConA 120 min 1287 ± 38 7.6 ± 0.2 45.0 ± 1.2 0.05

(a) Values obtained fitting the raw data by Global fitting of 1-componet 3D-Normal Diffusion function. (b) The diffusion coefficient was calculated from equation Equation S4 in SI. (c) Obtained applying the Stoke-Einstein equation to Dc. (d) Labeled by ATTO488.