Skip to main content
. 2013 May 20;16(5):252–260. [Article in Chinese] doi: 10.3779/j.issn.1009-3419.2013.05.07

2.

CTV及PTV的剂量分布比较

Dosimetric comparison of CTV and PTV

Studies Statistical index Data P
CI: conformity index; IC: inhomogeneity coefficient; CN: conformation number; DIBH: deep inspiration breath hold; SB+AC: shallow breathing with abdominal compression; 3D-CRT: three-dimensional conformal photon radiotherapy; IMRT: intensity-modulated photon radiotherapy; PBT: proton beam therapy; NC: not calculable.
Jiang 2006[7] CI
IC
CI: 3D-CRT vs IMRT vs PBT=1.54 vs 1.27 vs 1.21
IC: 3D-CRT vs IMRT vs PBT=0.4 vs 0.29 vs 0.59
NC
Wang 2009[9] CTV covered by 90% isodose line (%)
CTV covered by 95% isodose line (%)
3D-CRT vs PBT=99.0±0.4 vs 99.0±1.3
3D-CRT vs PBT=43.2±33 vs 86.4±12.5
0.57
< 0.001
Georg 2008[10] CI DIBH: 3D-CRT vs PBT=0.78±0.02 vs 0.53±0.08
SB+AC: 3D-CRT vs PBT=0.77±0.03 vs 0.54±0.08
< 0.001
< 0.001
Roelof 2012[12] CN 3D-CRT vs PBT=0.25±0.07 vs 0.25±0.08
IMRT vs PBT=0.38±0.1 vs 0.25±0.08
> 0.999
< 0.001