Skip to main content
. Author manuscript; available in PMC: 2019 Jun 1.
Published in final edited form as: IEEE Trans Med Imaging. 2018 Jun;37(6):1511–1521. doi: 10.1109/TMI.2018.2829896

TABLE II.

PSNR, ISNR, and SSIM Values of Images By Different Reconstruction Algorithms For The Cs Phantom

Incident photon Penalty Noise level (×10−5) PSNR I SNR SSIM
5×103 FDK 120 23.85 / 0.42
TV 3.51 29.82 5.97 0.96
Ours 3.46 33.95 10.10 0.97
1×104 FDK. 95.20 25.66 / 0.54
TV 2.79 31.32 5.66 0.97
Ours 2.74 35.18 9.52 0.99
5×104 FDK 52.10 27.93 / 0.77
TV 1.96 36.97 9.04 0.99
Ours 1.96 38.27 10.34 0.99