Table 3. Diagnostic Performance of DCE-MRI Histogram Metrics (Post-NAC and %Change) to Predict Good Response after NAC.

Metrics Post-NAC %Change
Mean 25th Percentile 50th Percentile 75th Percentile Skewness Kurtosis Mean 25th Percentile 50th Percentile 75th Percentile Skewness Kurtosis
Ktrans
 AUC 0.78 0.76 0.77 0.77 0.61 0.70 0.73 0.72 0.73 0.73 0.59 0.54
 CI 0.60–0.96 0.57–0.94 0.58–0.95 0.58–0.95 0.43–0.79 0.53–0.87 0.54–0.92 0.53–0.91 0.54–0.91 0.54–0.91 0.40–0.77 0.34–0.75
 Sensitivity 0.75 0.58 0.75 0.75 0.92 0.92 0.67 0.67 0.67 0.67 0.92 0.58
 Specificity 0.81 0.93 0.78 0.81 0.44 0.56 0.85 0.81 0.85 0.81 0.44 0.59
p value 0.002* 0.007* 0.005* 0.005* 0.223 0.021* 0.017* 0.022* 0.016* 0.015* 0.362 0.677
 Cutoff 0.11 0.04 0.10 0.14 0.21 −0.81 −59.69 −63.26 −60.14 −59.60 −35.12 −17.91
Kep
 AUC 0.78 0.81 0.81 0.80 0.76 0.75 0.70 0.73 0.69 0.69 0.69 0.69
 CI 0.63–0.93 0.67–0.94 0.67–0.95 0.66–0.95 0.59–0.93 0.57–0.93 0.54–0.86 0.58–0.89 0.53–0.86 0.53–0.86 0.5–0.87 0.49–0.9
 Sensitivity 0.92 1 1 0.92 0.58 0.58 1 1 1 0.92 0.67 0.58
 Specificity 0.56 0.59 0.59 0.59 0.89 0.89 0.48 0.52 0.48 0.52 0.78 0.85
p value < 0.001* < 0.001* < 0.001* < 0.001* 0.002* 0.006* 0.015* 0.004* 0.020* 0.020* 0.048* 0.065
 Cutoff 0.37 0.23 0.34 0.47 0.75 0.01 −16.92 −23.02 −19.32 −32.60 38.51 −102.36
Ve
 AUC 0.43 0.61 0.42 0.45 0.70 0.61 0.53 0.63 0.56 0.50 0.55 0.59
 CI 0.22–0.64 0.40–0.82 0.20–0.63 0.25–0.66 0.52–0.88 0.39–0.83 0.33–0.73 0.44–0.83 0.36–0.76 0.30–0.70 0.34–0.77 0.38–0.79
 Sensitivity 0.50 0.50 0.50 0.50 0.50 0.50 0.58 0.75 0.58 0.58 0.33 0.33
 Specificity 0.65 0.81 0.65 0.65 0.88 0.81 0.58 0.54 0.58 0.58 0.88 0.88
p value 0.505 0.314 0.442 0.643 0.029* 0.327 0.774 0.166 0.552 > 0.999 0.615 0.406
 Cutoff 0.51 0.29 0.50 0.62 0.75 0.24 −13.71 −12.58 −13.85 −9.20 130.61 −334.69

Optimal threshold was chosen according to Youden index. *Statistically significant differences (p < 0.05). %change = ([post-NAC values − pre-NAC values] / pre-NAC values) × 100.

AUC = area under ROC curve, CI = confidence interval, ROC = receiver operating characteristic