Skip to main content
. 2018 May;10(5):2567–2572. doi: 10.21037/jtd.2018.04.73

Table 3. Intraoperative parameters, main outcomes and complications.

Intraoperative parameters Mean SD Incidence %
Duration of anesthesia (min) 103.1 7
Duration of surgery (min) 128.2 14
GA induction to LMA insertion (sec) 113.2 7.8
LMA intracuff pressure (cmH2O) ≥60
Successful insertion and ventilation with LMA 52 96.3
Satisfactory fibre optic view through the LMA 52 96.3
Adequate end-tidal carbon dioxide during CMV 52 96.3
End-tidal carbon dioxide tension during CMV 5.6 0.47
Adequate paO2 and spO2 52 96.3
Intraoperative spO2 (%) 94.6 1.4
LMA insertion failure 1 1.9
Intraoperative leak during CMV 1 1.9
Pulmonary aspiration 0 0
Bleeding at 24 h 0 0
Suture dehiscence at 48 h 0 0
Mortality at 30 days 0 0

SD, standard deviation; GA, general anesthesia; LMA, laryngeal mask airway; CMV, controlled mandatory ventilation.