Skip to main content
. 2018 May;10(5):2760–2770. doi: 10.21037/jtd.2018.04.90

Table 2. Intraoperative variables of the patients.

Variable T1 T2 T3
C group P group P C group P group P C group P group P
Ppeak (cmH2O) 16.4±2.4 15.5±2.4 0.088 23.9±3.7 21.4±2.8 0.006 18.6±3.4 16.0±2.9 0.003
Cldyn (mL/cm H2O) 41.7±4.9 40.2±5.1 0.291 23.4±4.2 27.8±4.3 0.000 33.7±5.6 38.5±6.6 0.001
PaO2 (mmHg) 417.8±124.0 405.6±88.2 0.602 182.4±84.4 234.2±96.6 0.048 316.4±105.5 368.0±114.1 0.046
PaCO2 (mmHg) 41.7±3.4 39.3±4.4 0.258 39.9±4.9 42.7±4.6 0.286 40.9±5.3 39.5±4.8 0.369
HR (beats/min) 66.2±8.8 69.7±8.9 0.156 66.1±9.6 70.1±9.3 0.072 67.6±9.7 66.9±8.4 0.308
MAP (mmHg) 96.0±8.5 93.6±9.8 0.285 92.4±12.7 97.6±10.3 0.060 98.7±9.6 99.6±8.5 0.667
CVP (mmHg) 6.1±1.2 6.0±1.3 0.690 11.1±1.7 11.6±1.6 0.089 8.5±1.1 8.3±1.3 0.083
CO (L/min) 4.7±1.3 4.3±1.1 0.140 5.0±0.9 4.9±1.0 0.919 5.0±1.0 5.3±0.6 0.619

Numerical data are expressed as means ± SD. T1—endotracheal intubation for two-lung ventilation (TLV) when breathing and hemodynamics were stable; T2—after TLV was substituted with OLV when breathing and hemodynamics were stable; T3—OLV was substituted with TLV at the end of surgery when breathing and hemodynamics were stable. Ppeak, peak inspiratory pressure; Cdyn, dynamic compliance; PaO2, arterial oxygen tension; PaCO2, arterial carbon dioxide tension; HR, heart rate; MAP, mean arterial pressure; CVP, central venous pressure; CO, cardiac output.