Table 2.

Summary of Advanced Imaging Modalities for the Assessment of Barrett Esophagus

Modality Definition Equipment Field
Narrow-band imaging Uses blue-green spectrum of light (415-540 nm) to capitalize on the peak absorption of hemoglobin, accentuating visualization of the mucosal vasculature Olympus Field of view: 140°
Depth of field: 3-100 mm
Chromoendoscopy Absorptive and contrast stains applied to esophageal mucosa to highlight superficial mucosal architecture Stains, white-light endoscope NA
Confocal laser endomicroscopy Fluorescence emission by a low-powered laser that can generate in vivo images of esophageal mucosa at histologic-level resolution pCLE: Cellvizio, Mauna Kea Technologies
eCLE: Pentax confocal laser endomicroscope
pCLE field of view: 240-600 µm
Special resolution: 1.0-3.5 µm
eCLE field of view: 475 µm
Volumetric laser endomicroscopy Second-generation optical coherence tomography device; generates wide-field, cross-sectional views of the esophagus, allowing for a comprehensive assessment of the esophageal mucosa and submucosa NvisionVLE, NinePoint Medical Lateral resolution: 30 µm

eCLE, endoscope-based confocal laser endomicroscopy; NA, not applicable; pCLE, probe-based confocal laser endomicroscopy.