Skip to main content
. 2018 Jan 11;23(1):142. doi: 10.3390/molecules23010142

Table 4.

Chromatographic data, retention factor of first eluted enantiomer (k1), separation factor (α), resolution (RS), and elution order, for the chiral xanthonic analytes on the ChirobioticTM TAG column, under multimodal chromatographic conditions.

Analyte Elution Mode Mobile Phase k1 α RS First Eluted Enantiomer
1 POM 100% EtOH 1.26 1.24 0.60 (R)
2 NPM Hex:EtOH (70:30 v/v) 5.01 1.42 1.45 (R)
POM 100% EtOH 0.73 1.39 0.80 (R)
4 NPM Hex:EtOH (70:30 v/v) 10.66 1.38 1.76 (R)
POM 100% EtOH 1.21 1.36 0.92 (R)
5 NPM Hex:EtOH (70:30 v/v) 8.29 1.37 1.02 (R)
17 NPM Hex:EtOH (70:30 v/v) 0.80 2.77 3.87 (S)
30 NPM Hex:EtOH (70:30 v/v) 2.01 1.45 1.16 (R)
31 NPM Hex:EtOH (70:30 v/v) 1.57 1.27 0.50 (R)

Chromatographic conditions: flow rate: 0.2 mL/min, UV detection at 254 nm.