Maximum peak power (dBm in 50 MHz) for UWB systems.

Frequency (GHz) Maximum Peak Power Spectral Density (e.i.r.p.) (dBm in 50 MHz)
LT1 LT2 LEAS
f1.6 −50 −50 −50
1.6<f2.7 −45 −45 −45
2.7<f3.1 −36 −36 −36
3.1<f3.4 −36 −36
(0 with DAA) 1
−36
(0 with DAA) 1
3.4<f3.8 −40 0 1,2
(see note 1 for fixed outdoor)
20 1
3.8<f4.2 −60 0 1,2
(see note 1 and 3 for outdoor)
20 1
4.2<f4.8 −60 0 1,2
(see note 1 and 3 for outdoor)
0 1
4.8<f6 −30 −30 −30
6<f8.5 0 −30 −30
8.5<f9 −25
(0 with DAA)
−70 −30
9<f10.6 −25 −30 −30
f > 10.6 −45 −45 −45

1 Duty cycle of maximum 5% per second per transmitter on time (Ton). 2 Duty cycle limited to 1.5% per minute per transmitter on time (Ton) or an alternative mitigation technique should be used to achieve the same protection. 3 The maximum mean e.i.r.p. spectral density in the band 4.2 GHz to 4.4 GHz for emissions that appear 30° or greater above the horizontal plane should be less than −47.3 dBm/MHz, see clause 4.6.1.4 ECC/REC(11)09.