Skip to main content
. 2018 May 24;18(6):1705. doi: 10.3390/s18061705

Table 5.

Results of bogie fault diagnosis.

Test Accuracy Rate False Positive Rate False Negative Rate
Normal Fault1 Fault2 Fault3 Total
ELM 96.20% 63.33% 70.00% 74.00% 91.48% 3.80% 26.36%
SaE-ELM 96.80% 70.00% 73.33% 82.00% 93.11% 3.20% 20.91%
WELM 94.80% 80.00% 86.67% 90.00% 93.28% 5.20% 8.18%
WSaE-ELM 98.40% 90.00% 96.66% 96.00% 97.70% 1.60% 4.55%