Skip to main content
. 2018 Jun 8;9(2):39. doi: 10.3390/jfb9020039

Table 3.

Statistical summary of the effect of Aqua Titan-treated stockings worn during the 62-h recovery period after an uphill walk on muscle microvascular blood flow and oxygen consumption at rest and during 10% and 20% plantar flexion exercise, relative to the pre-walk baseline.

Contrast a Change Lower CI Upper CI p-Value Likelihood (%) Decrease/Trivial/Increase Qualitative b
mBF (mL·min−1·100 mL−1) Resting mBF (mL·min−1·100 mL−1)
14 h–BL AqT–Control 0.0715 −0.0918 0.235 0.368 10.0/18.5/71.5 Unclear
38 h–BL AqT–Control −0.0629 −0.171 0.0455 0.225 76.6/20.1/3.3 Likely decrease
62 h–BL AqT–Control 0.0413 −0.0372 0.120 0.269 2.75/32.1/65.2 Possible increase
10% Exercise mBF (mL·min−1·100 mL−1)
14 h–BL AqT–Control −0.141 −0.536 0.253 0.436 35.0/62.5/2.5 Possibly trivial
38 h–BL AqT–Control −0.154 −0.839 0.531 0.628 42.6/45.4/12.0 Unclear
62 h–BL AqT–Control 0.174 −0.529 0.876 0.593 11.3/43.5/45.2 Unclear
20% Exercise mBF (mL·min−1·100 mL−1)
14 h–BL AqT–Control 0.752 −1.24 2.75 0.407 6.52/34.9/58.6 Unclear
38 h–BL AqT–Control 0.104 −0.736 0.944 0.788 4.54/83.3/12.2 Likely trivial
62 h–BL AqT–Control 0.443 −0.703 1.59 0.409 2.81/56.5/40.7 Possibly trivial
mVO2 (mLO2·min−1·100g−1) Resting mVO2 (mLO2·min−1·100 g−1)
14 h–BL AqT–Control −0.0155 −0.0382 0.0072 0.154 86.6/11.1/2.24 Likely decrease
38 h–BL AqT–Control 0.0052 −0.0030 0.0134 0.188 0.55/42.2/57.3 Possible increase
62 h–BL AqT–Control −0.0051 −0.0135 0.0034 0.212 55.8/43.5/0.74 Possible decrease
10% Exercise mVO2 (mLO2·min−1·100 g−1)
14 h–BL AqT–Control −0.0852 −0.238 0.0677 0.236 60.5/38.1/1.33 Possible decrease
38 h–BL AqT–Control −0.0033 −0.104 0.0970 0.943 8.89/84.3/6.84 Unclear
62 h–BL AqT–Control 0.0310 −0.149 0.211 0.707 11.6/55.5/32.9 Unclear
20% Exercise mVO2 (mLO2·min−1·100 g−1)
14 h–BL AqT–Control −0.0973 −0.291 0.0960 0.284 54.6/43.6/1.77 Possible decrease
38 h–BL AqT–Control 0.0508 −0.215 0.317 0.680 12.7/49.3/38.1 Unclear
62 h–BL AqT–Control 0.144 −0.229 0.516 0.411 8.5/28.4/63.0 Unclear

a Data for each contrast are 14-h baseline, 38-h baseline and 62-h baseline. b The threshold for the smallest worthwhile change for a mechanism was 0.2 × SD [18]. The likelihood that a contrast was at least greater than the Cohen d threshold was: 25–75% possible; 75–95% likely; 95–99.5% very likely; >99.5% almost certain. Unclear refers to outcomes where the likelihood of both an increase and decrease exceeded 5% [18]. BL = baseline; AqT = Aqua Titan; 95% CI = confidence interval; mBF = muscle blood flow; mVO2 = muscle oxygen consumption; Hb = hemoglobin.