Skip to main content
. 2018 Jul;110(6):568–576. doi: 10.5935/abc.20180088

Table 6.

Body weight changes with AAC under 0.45 mm needle

  18 g/0.45 mm (n = 8) 22 g/0.45 mm (n = 7) 26 g/0.45 mm(n = 4)
Change in BW(g) 8.4 ± 0.8* 4.4 ± 0.8 2.4 ± 0.3

BW: body weight; AAC: abdominal aortic constriction. Data are presented as the mean ± SD.

*

p < 0.05 represents a significant difference between the 18 g/0.45 mm group and the 22 g/0.45 mm and 26 g/0.45 mm groups.