Acetone and isopropyl alcohol concentrations in fabrication and package plants.

Facility Process Isopropyl Alcohol Acetone
Number of Samples Number of No Detection Samples Range (ppm) Number of Samples Number of No Detection Samples Range (ppm)
Fabrication PHOTO 17 15 0.08–28.99 17 17
DIFF 7 4 0.26–0.81 7 4 0.02–0.15
CMP 4 3 0.26 4 4
T/F 4 4 4 3 0.06
IMP 3 1 0.25–0.26 3 2 0.01
ETCH 4 4 4 4
Package A/P 3 3 3 0 6.23–9.07
A/P cleaning room 1 1 1 0 9.66
D/A 4 4 4 0 0.96–4.32
Chip mounting 3 0 1.24–2.37 3 3
TDBI 7 7 7 7
SPP 1 0 8.28 1 1

PHOTO: photolithography, DIFF: diffusion, CMP: chemical mechanical polishing, T/F: thin film, IMP: ion implantation, ETCH: etching, A/P: adhesive print, TDBI: test during burn-in, SPP: solder ball paste print.