Skip to main content
. 2018 Jul 4;6(7):E789–E796. doi: 10.1055/a-0614-2390

Fig. 1.

Fig. 1

 Use of OTSC as a second-line treatment modality for a bleeding duodenal ulcer. a A visible artery was seen proximal to a previously deployed clip.  b The endoscope was equipped with an OTSC. Active bleeding occurred during suction. c The bleeding vessel was placed in the center of the OTSC cap and using the suction technique, the OTSC was deployed. The bleeding stopped completely. d There was no recurrent bleeding. The clip 24 hours later.