Skip to main content
. 2018 Jun 21;2018:4605191. doi: 10.1155/2018/4605191

Table 3.

Comparison of quantitative classification results based on different models.

Model Specificity Sensitivity Accuracy AUC F1
ResNet50 88.74% 77.39% 84.94% 0.91 0.78

Xception 87.16% 77.44% 84.06% 0.90 0.76

InceptionV3 89.06% 77.44% 85.13% 0.91 0.78

CNN3 79.22% 63.19% 74.44% 0.78 0.60

Traditional model 74.61% 58.10% 70.55% 0.73 0.49