Skip to main content
. 2018 Jun 25;9(7):3244–3265. doi: 10.1364/BOE.9.003244

Table 1. Performance Comparison Between DRUNET and Patch-Based Segmentation.

Metrics Tissue DRUNET Patch-Based
Healthy Glaucoma Healthy Glaucoma
Dice coefficient
(Mean ± SD)
RNFL 0.922 ± 0.052 0.921 ± 0.031 0.821 ± 0.040 0.814 ± 0.038
Retinal Layers
(all others)
0.951 ± 0.010 0.960 ± 0.030 0.872 ± 0.034 0.863 ± 0.081
RPE 0.831 ± 0.045 0.841 ± 0.034 0.857 ± 0.018 0.861 ± 0.060
Choroid 0.906 ± 0.035 0.912 ± 0.050 0.862 ± 0.013 0.859 ± 0.025

Sensitivity
(Mean ± SD)
RNFL 0.923 ± 0.012 0.925 ± 0.032 0.897 ± 0.041 0.883 ± 0.012
Retinal Layers
(all others)
0.960 ± 0.038 0.966 ± 0.032 0.981 ± 0.010 0.983 ± 0.002
RPE 0.870 ± 0.043 0.888 ± 0.033 0.915 ± 0.052 0.899 ± 0.090
Choroid 0.890 ± 0.060 0.911 ± 0.020 0.882 ± 0.021 0.871 ± 0.062

Specificity
(Mean ± SD)
RNFL 0.993 ± 0.005 0.994 ± 0.002 0.989 ± 0.002 0.988 ± 0.001
Retinal Layers
(all others)
0.995 ± 0.001 0.996 ± 0.001 0.991 ± 0.004 0.989 ± 0.003
RPE 0.993 ± 0.000 0.993 ± 0.004 0.989 ± 0.003 0.990 ± 0.000
Choroid 0.996 ± 0.022 0.994 ± 0.004 0.993 ± 0.002 0.991 ± 0.005