Skip to main content
. 2018 Jun 6;9(7):2930–2942. doi: 10.1364/BOE.9.002930

Fig. 3.

Fig. 3

A) Measured (blue) and simulated (solid red) refractive index of water. Results are obtained over 13 independent measurements. The mean percentage error between 0.2 – 1 THz is 5%. B) Measured (blue) and simulated (solid red) absorption coefficient of water. Results are obtained from 8 independent measurements. The mean percentage error between 0.2 – 1 THz is 10%. The values of parameters used in simulation were ε = 3.2, εs = 78.4, ε1 = 4.9, τ1 = 8.0ps and τ2 = 0.18ps.