Skip to main content
. 2018 Jul 1;198(1):77–89. doi: 10.1164/rccm.201707-1404OC

Table 6.

Children’s Hospital of Philadelphia Patients Only, Multivariable Model for ICU Mortality Including Data from Day 1 of Mechanical Ventilation (n = 427)

Variable Odds Ratio (95% CI) P Value
PEEP lower than ARDSNet (vs. on-protocol/high PEEP) 0.87 (0.32–2.35) 0.78
PRISM III* 1.10 (1.07–1.14) <0.001
Immunodeficiency (vs. no immunodeficiency) 2.80 (1.26–6.24) 0.012
Stem cell transplant (vs. no stem cell transplant) 4.70 (1.69–13.2) 0.003
PF ratio (Day 1)* 0.995 (0.989–1.0001) 0.06

For definition of abbreviations, see Table 5.

PEEP lower than recommended by the ARDS Network Protocol for a given FiO2 did not remain independently associated with mortality after multivariable adjustment.

*

Variables treated as continuous in the multivariable model.