Skip to main content
. Author manuscript; available in PMC: 2019 Jun 1.
Published in final edited form as: J Biomed Mater Res A. 2018 Feb 23;106(6):1753–1764. doi: 10.1002/jbm.a.36360

Figure 3.

Figure 3

Biophysical characterization of PLGA-PEG-AXT050 nanoparticles. A The PLGA-PEG-AXT050 nanoparticles have a hydrodynamic particle diameter of approximately 65-80 nm. B Hydrodynamic particle diameter increased slightly as the percentage of AXT050 peptide conjugation increased. C Particle zeta potential was determined to be approximately -20 mV, without AXT050 conjugation content significantly affecting the surface charge.