Table 1. Volume results of using automatic segmentation (Vol 1), manual segmentation using just the first and last slice (Vol 2) and manual segmentation each forth slice (Vol3), of cone beam computer tomography from upper canines (FDI 13, 23).
Individual | Vol 1 (mm3) | Vol 2 (mm3) | Vol 3 (mm3) |
---|---|---|---|
1 | 10.87 | 10.6 | 13.2 |
2 | 16.03 | 17 | 19.7 |
3 | 16.4 | 20.9 | 19.8 |
4 | 9.309 | 12.9 | 14.8 |
5 | 5.478 | 7.1385 | 8.04 |
6 | 11.25 | 12.5 | 12.6 |
7 | 13.26 | 25.9 | 16.3 |
8 | 16.72 | 17 | 23.2 |
9 | 37.01 | 32.6 | 41.9 |
10 | 16.98 | 23.4 | 28.9 |
11 | 11.77 | 19.2 | 17.7 |
12 | 5.857 | 8.7131 | 11.7 |
13 | 9.107 | 13.3 | 28.3 |
14 | 17.24 | 33 | 29.8 |
15 | 12.76 | 27.5 | 21.1 |
16 | 15.87 | 16.1 | 27 |
17 | 13.2 | 19.7 | 22.6 |
18 | 11.61 | 19.7 | 16.5 |
19 | 24.52 | 35.3 | 40 |
20 | 15.51 | 22.1 | 22.1 |
21 | 17.6 | 29.3 | 35.5 |
Mean | 14.68 | 20.18 | 22.41 |